In the vertical drop impact test, it is a vertical ball drop

The application and operation method of GB4706.1-50mm round baffle plate test finger: in compliance with regulations: GB/T16482-2008 Figure 2, IEC61032 Figure 2, GB/T16842 and GB4208 IP2, IEC60529 IP1, IEC60065, main purpose: to detect and avoid the body The basic safety protection of the components that touch the risk is also used to avoid the safety protection detection of the finger touch. Sample category: the energized component or mechanical part of the casing that is very easy to touch. The structure and function: imitate the human finger , It is composed of finger, middle finger, finger seat and edge rocker. There are two themes of movable bone joints, which can bend within 90°.

In the vertical drop impact test, the vertical ball falls. As shown in the figure below, select the vertical ball and hook one end of the galvanized steel wire rope to the hook. The vertical bearing steel ball just touches the test level surface, and then the scale is lowered by 100 mm. , The falling aspect ratio is 1300Mm, and then the bearing steel ball is placed in the vertical position to release the electromagnetic coil. Fix the brake pedal equipment on the fixed wheels to prevent the equipment from moving.

In the shaking impact test, select the horizontal ball, hook one end of the galvanized steel wire rope to the hook, and place the horizontal ball on the horizontal ball to release the electromagnetic coil by the IP protection level test tool, and then move the hook seat to make the galvanized steel wire rope Straighten it and clamp the hook seat tightly. Then when the horizontal ball is vertical, it just touches the test vertical surface (the impact point aspect ratio can be manipulated according to the remote control), and then the horizontal ball is placed on the horizontal ball to release the electromagnetic coil to run. Fix the brake pedal equipment on the fixed wheels to prevent the equipment from moving.

The scope of application of the yellow impact hammer: it is used to test the housing of household appliances and similar home appliances, the actual operating rod, the rocker, the knob, the indicator light and other housings to bear the impact of mechanical equipment. Various specifications and models such as 0.14, 0.2J, 0.35J, 0.50J, 0.70J, 1J and 2J are used for the implementation of different standard tests. To match the IEC60335 and GB4706 specifications, the impactor of 0.5J±.04J is used. For lighting products, the specifications and models such as 0.2J, 0.35J, 0.5J and 0.70J can be used. Others can be adopted according to the product regulations.

The main purpose: the impact device simulates the mechanical equipment collision that is likely to be encountered in all normal applications of the equipment. It is used to check the equipment casing to bear the impact of the mechanical equipment. Applicable to household appliances and similar main purposes for household appliances, electronic equipment, lighting fixtures, electrical accessories, actual operating rods, joysticks, knobs, indicator lights, signal indicators and lamp covers, etc. to carry out impact toughness tests to ensure that they are Trial products can bear the reckless actual operation and other accidents that are likely to occur, so that all home appliances can be trusted to operate normally.

Hot-dip galvanized layer adhesion test-thumping test equipment: 1. Product description: This test equipment conforms to the falling weight test method of GB/T2694-2010 and YDT757 specifications, and is suitable for hot-dip galvanized layer adhesion test. The drill bit was dropped randomly and hit the sample to check whether the hot-dip galvanized layer was in compliance with the specification. This product is suitable for manufacturers and quality inspection units of similar towers to carry out product quality inspection and manipulation.

Drill bit quality: 210g±1g, 45 steel, hardened to above HS40 2. Vertical aspect ratio of drill bit axis to base surface: 300mm±1mm 3. Hammer handle material: red oak 4. Base plate 250×250×15mm , Equipped with level bubble, adjustable level

Operation method: Adjust the equipment according to the cabinet countertop level to make it level, adjust the sample so that the severe strike point is not less than 11mm from the edge, corner, and top of the sample, the drill bit faces the assembly platform management center, and the plan view of the hammer handle and the base is vertical After falling down randomly, hit 5 points on the parallel surface with a pitch of 4mm. Check whether the surface condition of the hot-dip galvanized layer meets the regulations, and the severe strikes should not be severed repeatedly

Maintenance and maintenance: The whole set of equipment has long been solved with anti-rust treatment, anti-fouling and anti-humidity. Keep the inner hole of the rubber bearing smooth and level.
Previous:
Standard test pointer pin briefly describes what is a spring fatigue testing machine
Next:
The waterproof grade of electronic products JIS (IPX)

Contact us

Add:1F, Gongle Fenghe Park, Xixiang Avenue, Baoan District, Shenzhen,China
Tel:0755-23702756
Fax:0755-23702758
Contact:Mr.Wu 13631576199
Email:szcx17@163.com
  1. Advisory

  2. Mobile Site

Copyright 2021 Shenzhen Chuangxin Instrument Co., Ltd. All Right Reserved.