Do you know the temperature rise test angle of the generator?

When the generator is running, mechanical loss, copper loss, iron loss and other losses will occur. These losses are converted into heat. L4931CDT50-TR will increase the temperature of all parts of the generator, while the cooling medium will continue to take away heat. At the same time, when the heat taken away is equal to the heat lost, the temperature of each part of the generator will stabilize at a certain value.

When the load and cooling conditions of the generator change, the temperature of each part of the generator also changes. Determine the material and structure of the generator, and determine the allowable temperature. In any case, the high temperature of each part of the generator must not exceed the high allowable temperature of the edge material used, otherwise it will cause thermal aging or damage, which will greatly shorten the service life of the motor.

The so-called generator temperature rise test angle test is to make the generator run with load under the required conditions, record the stable temperature rise of each component, and draw the generator's temperature rise curve.

Purpose of temperature rise test
① The temperature rise test of the newly installed generator is to determine its load capacity and overload capacity to see if it meets the design and manufacturing requirements;
②Determine that the generator is within the allowable voltage fluctuation range and the temperature of the cooling medium is not at the same time, and provide the limit relationship curve of active and reactive power to provide the operating limit diagram of the generator;
③Determine the relationship between the average winding temperature, the high heating point temperature and the temperature of the thermometer to determine the monitoring of the temperature limit of the generator winding; ④ Perform temperature rise test on defective or improved output generators to determine reasonable output;
⑤ If you have any questions about the cooling system of the generator, please conduct a temperature rise test to verify its cooling efficiency, so as to provide a basis for maintenance and improvement of the ventilation system and cooling system.
Previous:
Test tools are more convenient to test chips
Next:
Standard test pointer pin briefly describes what is a spring fatigue testing machine

Contact us

Add:1F, Gongle Fenghe Park, Xixiang Avenue, Baoan District, Shenzhen,China
Tel:0755-23702756
Fax:0755-23702758
Contact:Mr.Wu 13631576199
Email:szcx17@163.com
  1. Advisory

  2. Mobile Site

Copyright 2021 Shenzhen Chuangxin Instrument Co., Ltd. All Right Reserved.